ITEM |
OSC-1060 |
|
CRT |
Configuration and Useful Screen |
6-Inch Recrangular Screen with InterNal Graticule : 8 X 10 div(1 div-1cm)
Marking for Measurement of Rise Time 2 mm Subdivisions Along The Central Axis. |
|
Accelerating Potential |
+10KV Approx(Ref. Cathode) |
|
Phosphor |
P31(Standard) |
|
Focussing |
Possible(With Auto-Fous Corrnetion Circuit) |
|
Trace Rotation |
Provided |
|
Intensity Control |
Provided |
|
2-AXIS INPUT
(INTENSITY MODULATION |
Input Signal |
Positive Going Signal Decreases intensity +5 Vp-p or More Signal Cases Noriceable Modulation at Normal Intensity Settings |
|
Bandwith |
DC to 2MHz(-3 dB) |
|
Coupling |
DC |
|
Input Impedance |
20kΩ -30Ω Typical |
|
Maximum Input Voltage |
30V(DC-PEAK AC) |
|
VERTICAL DEFLECTION |
Bandwith (-3dB) |
DC Coupled |
DC to 60MHz Normal
DC to 10MHz Magnifed |
|
AC Coupled |
10Hz to 60MHz Normal
10Hz to 10MHz Magnifed |
|
Modes |
CH1, CH2, DUAL, ADD, ALT, CHOP |
|
Deflection Factor |
5mV/div to 5V/div in 11 Calibrated Steps of A 1-2-5 Sequence
Continuously Variable Between Steps at Least 1:2.5 |
|
Accuracy |
Normal : ±3%, Magnified, ±5% |
|
Input Impedance |
1㏁ in Parallel with Approx, 30pF |
|
Maximum Input Voltage |
Direct 400V(DC+Peak AC), with Probe : Refer to Probe Specification |
|
Input Coupling |
DC - GND - AC |
|
Rise time |
5.8ns or Less(35ns or Less : X 5MAG) |
|
CH1 Out |
20mV/div into 50Ω : DC to 10MHz(-3dB) |
|
Polarity Inversion |
CH2 Only |
|
HORIZONTAL DEFLECTION |
Display Modes |
Normal, X-Y, x10, Variables |
|
Time Base |
0.1µs/div to 0.2s/div in 20 Calibrated Steps, 1,2-5 Sequence
Un-calibrate Continuous Control Between Steps at Least 1:2.5 |
|
Sweep Magnification |
10 Times (Maximum Sweep Rate : 10ns/div) |
|
Accuracy |
±3%, ±5%(0'C to 40'C), Additional Error for Magnified ±2% |
|
TRIGGER
SYSTEM |
Modes |
Auto, Normal, TV-V, TV-H |
|
source |
Ch1, VERT(CH1, CH2)EXT, LINE |
|
Coupling |
AC |
|
Slope |
+ or - |
|
Sencitivity and Frequency Auto(30Hz or More), Nom |
AREA |
DC to 10MHz |
10MHz to 60MHz |
|
INT(VERT) |
0.5 div(2.0) |
1.5div(3.0) |
|
EXT |
0.2 Vp-p |
0.6 Vp-p |
|
TV-V, TV-H |
At Least 1 div or 1.0 Vp-p |
|
External Trigger Input Impedance |
1mΩ(in Parallel with Approx, 25pF |
|
Max Input Voltage |
400V(DC+Peak AC) |
|
X-Y OPERATION |
X-Axis, Y-Axis |
(Same as CH1 Except for The Following) Deflection Factor : Same as That of CH1 Accuracy : ±5%
Frequency Reaponse : DC to 500KHz(-3dB) |
|
X-Y Phase Difference |
3' or Less (AtDC to 50 KHz) |
|
CALIBRATOR |
Probe Adjustment |
1KHz(±20%) Frequency, 0.5V(±10%)Square Wave Duty Ratio : 40~60% |
|
POWER SUPPLY |
Voltage Range |
Voltage Range |
Fise(250V) |
|
UL198G |
IEC127 |
|
115(98~125V)/AC |
F1.25 AL |
F1.25 AL |
|
230(198~250V)/AC |
F0.63 AL |
F0.63 AL |
|
Frequency |
50/60 Hz |
|
Power Consumption |
Max 4.5W |
|
PHYSICAL CHARCTERISTICS |
Weight |
8.2Kg |
|
Size |
370mm(W) x 137mm(H) x 416mm(D) |
|
ENVIRONMENTAL CHARACTERISTICS |
Temperature |
Temperature Range fot Rated Operation : + 10'C to +35'C(+50"F to +95'F) Max Ambient Operting Temperature : 0'C to 40'C(+32'F to +104'F) Max Storage Temperature : -20'C to +70'C(-4'F to +158'F) |
|
Humidity |
Range for Rated Operation : 45% to 85% RH/Max Ambient Operating Humidity : 35% To 85 %RH |
|
OTHERS |
Accessories |
Operator's Manual :1 Spara fuse : 1 |
|
Supplied |
Power cord : 1 Test Probe(option) : 2 |